Model TDS Driver Baud Rate Parity Note
C 100 D50 / C100 4800 None
D 50 D50 / C100 4800 None
A 5 TOP GUN 4800 None
A 10 TOP GUN 4800 None
A 20 TOP GUN 4800 None
DTM 420 DTM 400/500 4800 None Older gun; If your Survey Pro does not have DTM400/500 driver, you will have to hand enter the readings from the gun.
DTM 550 DTM 400/500 4800 None
DTM 520 DTM 400/500 4800 None
DTM 700 SETS 1200 None
NPL 820 SETS 9600 None Must be in TDS software to work with external data collector.
DTM 851 SETS 9600 None


SETs mode works on guns with BIOS 1.11 or newer. To see the Bios press the [FNC] key then the 9 key.

Nikon instruments that support the SETS protocol may be operated under either LIETZ or SETS.

Set the "Data OUT" feature inside the Nikon Setup to "RSNikon" or "RS232 Nik" to send the shot data out to the DC. To get to the setup screens, turn the gun off and hold the 2nd Function key while turning the unit back on.

Nikon DTM-300 is not "hard coded" to 1200 baud when SETs is selected. You must manually change the baud rate on the Gun.