Tripod Data Systems
About TDS Contact us My account
Advanced search
What's NewProductsHow To BuySupportPress Room
 

Nikon Instruments

Model TDS Driver Baud Rate Parity Note
C 100 TopGunC100 4800 None  
D 50 TOPGUN-D50 4800 None  
A 5 TOPGUN 4800 None Older gun; If your Survey Pro does not have DTM400/500 driver, you will have to hand enter the readings from the gun.
A 10 TOPGUN 4800 None
A 20 TOPGUN 4800 None
DTM 420 Topgund420** 4800 None
DTM 550 DTM 400/500** 4800 None
DTM 520 DTM 400/500** 4800 None Must be in TDS software to work with external data collector.
DTM 700 SETs 4800 None
NPL 820 SETs 4800 None
DTM 851 SETs 4800 None


Many 4.1 Survey Standard cards will not talk to Nikon guns using the TOPGUN setting. These guns must use the Leitz/Sets setting. There is no other work-around, except the upgrade.

On TDS Cables, look for the NKN inscription.

Set the "Data OUT" feature inside the Nikon Setup to "RSNikon" or "RS232 Nik" to send the shot data out to the DC. To get to the setup screens, turn the gun off and hold the 2nd Function key while turning the unit back on.

Nikon DTM-300 is not "hard coded" to 1200 baud when SETs is selected. You must manually change the baud rate on the Gun.

**Nikon instruments that support the SETS protocol may be operated under LIETZ and SETS